Bd vacutainer k2 edta msds pdf

Bd is the inventor of bd vacutainer blood collection tubes as well as the worldwide leader in blood tubes. Cytochex bct is a direct draw blood collection tube that maintains cellular morphology and surface antigen expression, including cluster of differentiation cd markers prior to analysis by flow cytometry. There are no functional differences between the two additives. Bd vacutainer spraycoated k 2 edta tubes are used for whole blood hematology determinations and immunohematology testing. Bd vacutainer cpt is a fullyclosed system for separation of mononuclear cells from whole blood, where cell separation is carried out in the primary blood collection tube. Tubes with a bd hemogard closure incorporate a plastic shield that protects lab personnel from contact with blood on the stopper or around the outer rim of the tube. Identical to the conventional glass and plastic bd vacutainer tubes, except for the additional safety feature of a protective shield over the rubber stopper.

Block scientific represents the highest quality equipment made by the leading manufacturers of clinical laboratory equipment in the world. Edta is the preferred anticoagulant over heparin because heparin is only effective for 2436 hours. Bd vacutainer tubes containing sodium fluoride and disodium edta bd microtainer tubes containing sodium fluoride and disodium edta after swallowing. It is intended for the purposes of molecular diagnostic testing. Bd vacutainer plastic blood collection tubes with k2edta. Pathology personnel draw blood cultures during am phlebotomy rounds and in. Use a microtainer with k2edta for capillary lead specimens only. I would like to know how to prepare edta to use as an anticoagulant for blood collection, and i have 0. Bd vacutainer hemogard closure plastic k3edta tube capacity. Bd vacutainer brand sst tubes containing silica and gel. Bd vacutainer color chart baptist health south florida. Jul 06, 2018 accessgudid bd vacutainer edta k2 blood collection tubes 50382903666435 bd vacutainer edta k2 blood collection tubes skip to main content u. Different phlebotomy tubes are identified by the color of the stopper or shield.

What is the difference between k2 edta and k3 edta. Click the button below to add the bd 367855 vacutainer plus plastic blood. The vacuette k2 edta blood collection tube is a lavender top tube from greiner bioone which is used primarily in hematology. The additives contained in bd vacutainer fluorideoxalate and fluorideedta tubes will stop enzymatic activity at the glycolytic pathway. Bd vacutainer venous blood collection tubes, bd diagnostics. However, the data is provided without any warranty, expressed or implied, regarding its correctness or accuracy. Bd bbl collection and transport systems bbl vacutainer anaerobic specimen collector sterile bd cultureswab maxv. Bd 367841 vacutainer plus plastic blood collection tubes edta. Safetylok or bd vacutainer push button blood collection set. Medical grade pet tube, size x 75mm k2 edta spray. Bd vacutainer color chart stopper color coding additive laboratory use min. Recommendation disposal should be done in accordance with all federal, state and local environmental regulations. Wilburn medical is your online medical clinic supply store.

Vacutainer brand cpt tm cell preparation tube w sodium citrate. Bd vacutainer spraycoated edta tubes are used for whole blood hematology determinations, immunohematology testing and blood donor screening. Bd vacutainer and microtainer brand plasma separator tube with lithium heparin. Generally, k2 or k3 potassium salt of edta ethylene diamine tetra acetic acid is used as an anticoagulant. Acda anticoagulant citrate dextrose solution, solution a, usp 2. Bd vacutainer venous blood collection tube serum tube clot activator additive x 100 mm 5 ml orange bd hemogard closure polyethylene terephthalate pet tube 100box, 10 boxcase bd. Bd vacutainer plastic k 2 edta tubes krackeler scientific. See section 7 for information on safe handling see section 8 for information on personal protection equipment. Potassium edta k2 or k3 is more preferred, rather than sodium edta. We are currently receiving a high volume of calls due to a strong demand for products which are now being manually assigned.

Shop online for a wide selection of bd vacutainer plastic blood collection tubes with k2edta. Bd vacutainer plus plastic k2 edta tubes henry schein. Working safely with hazardous chemicals manual contains all coulter material safety data sheets msds. Bd vacutainer venus blood collection tube for plasma preparation, pk100, bd 362788 vt362788 is part of a wide selection of bd disposable supplies. What is the difference between k2 edta and k3 edta pediaa. Tubes with spraycoated k 2 edta, the anticoagulant of choice in specimen collection and cell blood counting requires eight to ten inversions for thorough mixing of blood and anticoagulant plastic tubes offer a safer alternative to glass, are virtually breakresistant, and can be incinerated. Bd vacutainer plastic blood collection tubes with k 2 edta. It is an aminopolycarboxylic acid and a colorless, watersoluble solid.

Greiner bioone is your leading global partner all information about k2e k2edta contact us or buy online at shop. Sept 12 2016 vacuette k2e k2edta blood collection tube. K2 edta solution is spraydried in the interior surface of plastic tubes while k3 edta solution comes as a liquid in glass tubes. Bd, the bd logo and all other trademarks are the property of becton, dickinson and company or its affiliates. If conta see msds store tightly closed at 1530c lot no 68683 newcomer supply co. Vacutainer hemogard closure plastic k2edta tube contains k2edta which is a liquid solution that is spray coated onto the interior surface of the bd vacutainer plus tubes. Bd vacutainer heparin tubes continued reference number glass g or plastic p tube size mm draw volume ml closure typecolor label type additive concentration. Avoid opening the tube as it may introduce contamination. Medical grade pet tube, size x 100mm k2 edta spray. Used to obtain a whole blood or edta plasma sample.

Bd vacutainer brand tube with tripotassium edta 16 other information. Vacutainer tubes, as they are collectively called, were developed by joseph kleiner in 1947 and are currently being produced by becton, dickinson and company, a global provider of medical supplies to the healthcare and pharmaceutical industry. Bd vacutainer plastic chemistry tubes javascript seems to be disabled in your browser. Standard must be consulted for specific requirements u. The inner wall of vacuette edta tubes is coated with spraydried k2edta or k3edta. Bd vacutainer brand tube with tripotassium edta y additional information. See medline canada covid19 communication april 6th. Learn more about edta uses, effectiveness, possible side effects, interactions, dosage, user ratings and products that contain edta. The bd p100 tube contains spraydried k2edta anticoagulant and proprietary additives. Bd diagnostics preanalytical systems product catalog bd. Bd vacutainer hemogard closure plastic k2edta tube capacity. Bd vacutainer edta tube with bd hemogard closure lavender. Disposal must be made according to the regulations found in 40 cfr 261.

The inner wall is coated with spraydried k2 edta which acts as an anticoagulant, binding calcium ions and interrupting the clotting cascade. Bd becton, dickinson and company diagnostic systems. For the best experience on our site, be sure to turn on javascript in your browser. Material safety data sheet may be used to comply with oshas hazard communication standard, 29 cfr 1910.

Hemogard closure plastic k3 edta tube contains the additive k3 potassium salt of edta that acts as a coagulant. Bd vacutainer venous blood collection tube guide bd diagnostics preanalytical systems 1 becton drive franklin lakes, nj 07417 usa invert gently, do not shake the performance characteristics of these tubes have not been established for infectious disease testing in general. The procedure provides instructions for sterile collection of blood samples for aerobic and anaerobic culture. The performance characteristics of these tubes have not been established for infectious disease testing in general. The main difference between k2 edta and k3 edta is that k2 edta contains two chelated potassium ions whereas k3 edta contains three chelated potassium ions. Bd vacutainer venous blood collection tube whole blood k2 edta additive x 75 mm 2 ml lavender bd hemogard closure plastic tube 100box bd 367841. Bd vacutainer ppt is a closed system allowing separation and storage of undiluted edta plasma in the primary blood collection tube. K 2 edta is the anticoagulant of choice in specimen collection and blood cell counting according to both nccls and the international council for standardization in haematology icsh. Ethylenediaminetetraacetic acid edta, also known by several other names, is a chemical used for both industrial and medical purposes. A chelating agent is a clawlike substance that can grab and stick to other molecules. Specimen collection and transport chart tests pr oduct c. We offer new as well as refurbished products from leading manufacturers in the industry. Bd 367855 vacutainer plus plastic blood collection tubes.

Shield design is engineered to protect lab personnel from direct contact with blood on the stopper or around the outer rim of the tube, as well as from blood splattering upon opening the tube. To the best of our knowledge, the information contained herein is accurate. There is no manual influence on the drawing of blood so the process remains. Edta acts as an anticoagulant, binding the calcium ions and interrupting the clotting cascade. Bd vacutainer edta lavender, tan, and pink top tubes and bd vacutainer lithium heparin green top tubes can cause an underestimation of lead in blood samples when used with magellan diagnostics leadcare assays, employing the anodic stripping voltammetry asv methodology, or any other assay employing asv methodology. The bd p100 tube contains spraydried k2edta anticoagulant and. Sterile vacuum blood collection bd vacutainer tubes are for serum. Bd vacutainer plastic k2edta tube with lavender bd hemogardtm closure. The tubes are available in a range of sizes in both plastic and glass and can be identified by a lavender cap. This decreases the complexity of steps for mononuclear cell separation, thereby minimizing variability from sample processing. Fungal and acid fast bacillus afb blood cultures are collected using the same arm preparation. Department of labor occupational safety and health administration nonmandatory form from approved omb no. Tube stopper evacuated blood collection tubes for whole blood. Furthermore, k2 edta slightly increases the mcv mean corpuscular volume of red blood cells at higher concentrations while k3 edta has no influence on the mcv of red blood cells at higher.

Safety data sheet vacuette k2e k2edta page 1 4 blood. We do not have any document for this combination of countrylanguage and catalog number. Bd vacutainer brand plus serum tubes and plastic trace element serum tube. Helpingallpeople livehealthylives bdvacutainer tubeguide edta serum glucose specialty sst pst heparin citrate tolearnmoreaboutthefullproductofferingofbdvacutainer. Evacuated sterile blood collection tube for whole blood haematology determination. Block label and lavender bd hemogard safety closure. Bd vacutainer venus blood collection tube for plasma. Bd vacutainer edta tubes are used to obtain a whole blood or edta plasma sample. We support our products with extensive clinical expertise and educational materials to help you achieve the best possible results. Identification product identifier bd vacutainer k2edta tubes other means of identification 362089, 364661, 364664, 367838, 368274, 368499.

Safety data sheet according to federal register vol. Bd vacutainer venus blood collection tube for plasma preparation, pk100, bd 362788 is one of the many quality laboratory and scientific products we have to offer at very competitive pricing. The bd best practice formulary bpf, as it relates to bd vacutainer blood collection tubes, was developed to provide customers with a condensed yet comprehensive array of bd vacutainer blood collection tubes for virtually every clinical need. Bd, the bd logo and all other trademarks are property of becton, dickinson and company. Bd vacutainer brand plus serum tubes and plastic trace element serum tube to prevent contact with skin and eyes. How to prepare edta as anticoagulant for human blood.

Blood collection set with 12 inch tubing such as the bd vacutainer safetylok. The information in edta msds was obtained from current and reliable sources. Furthermore, k2 edta slightly increases the mcv mean corpuscular volume of red blood cells at higher concentrations while k3 edta has no influence on the mcv of red blood cells at higher concentrations. If youre searching online to find deals to buy medical equipment and wholesale medical supplies at a low price, wilburn medical has the selection of supplies youve been looking for at a great price.

Uses, side effects, interactions, dosage, and warning. Evaluation of vacuette k edta and k evacuated blood. Bd vacutainer tubes for glucose and lactate determination. Bd vacutainer edta tubes bd vacutainer spraycoated edta tubes are used for whole blood hematology determinations, immunohematology testing and blood donor screening. Acda is used as an anticoagulant in the extracorporeal blood processing with autologous prp systems in production of plateletrich plasma prp. Edta is added to blood collection tubes to transport specimens for analysis in chemistry e. Greiner bioone is your leading global partner all information about edta contact us or buy online at shop. The phlebotomist collects a 3 or 4ml k2 edta ethylene diaminetetracetic acid tube, used for a cbc on all sps aged 1 year and older, following the established venipuncture protocol and. Jan 22, 2019 the main difference between k2 edta and k3 edta is that k2 edta contains two chelated potassium ions whereas k3 edta contains three chelated potassium ions.